UHV Power Transmission & Transformation Project

The Baihetan–Jiangsu ±800 kV UHV DC transmission project uses premium high-permeability oriented silicon steel in every converter transformer. Converter transformers are not ordinary power transformers; they sit at the point where AC meets DC, and the core sees both AC flux and a small DC bias. That combination changes the CRGO specification in ways that ordinary grid transformers never encounter.

What Makes a Converter Transformer Different

An ordinary AC transformer sees pure alternating flux. A converter transformer’s valve-side winding carries a DC component from rectification. Consequently, the core operates with a small DC bias on top of the AC cycle. That bias pushes the operating flux closer to saturation.

Standard CRGO at the bias point would saturate, overheat, and hum loudly. High-permeability Hi-B CRGO has a statter B-H curve—meaning it carries more flux before saturation, giving the design margin needed to absorb the DC offset.

Why Ultra-Low Core Loss Matters at 800 kV

At ±800 kV and thousands of megawatts, even a 0.1 W/kg difference in core loss translates to megawatts of continuous transmission loss over a year. The Baihetan project specifies Hi-B grades (B23R085 or equivalent) rather than conventional 30Q120, because:

  • Lower no-load loss across thousands of kilometers of line.
  • Cooler core operation under DC bias.
  • Reduced audible noise—a real concern for converter stations near populated areas.
  • Tighter thickness tolerance (±0.01 mm) to balance flux in large cores.

converter transformer CRGO

UHV vs. Ordinary Transformer: The CRGO Spec Difference

表格

Parameter Ordinary 220 kV Transformer ±800 kV Converter Transformer
Grade 30Q130 or M5 B23R085 / 27Q110 Hi-B
Thickness 0.30 mm 0.23–0.27 mm
Thickness tolerance ±0.02 mm ±0.01 mm
DC bias margin Not considered Designed into core
Noise target Standard Strict site limits
Coating C-2 C-4 high-temperature

Lamination and Core Forms That Scale Down

The same Hi-B logic applies to smaller grid-tied and industrial transformers that face harmonics or DC offset:

  • Silicon Electrical Steel Sheet EI96 #2 provides a cost-effective EI lamination stock for small control and isolation transformers.
  • For converter-grade applications at smaller ratings, specify B-series Hi-B in coil form rather than standard CGO—the harmonic content from rectifiers behaves like a small DC bias even at low power.

What Buyers Should Specify

When ordering CRGO for converter, rectifier, or inverter-duty transformers, write into the PO:

  • Hi-B grade (B-series or equivalent), not conventional CGO.
  • Thickness tolerance ±0.01 mm.
  • C-4 high-temperature coating.
  • Mill certificate showing actual B₈₀₀ and P₁.₇/₅₀, not just grade compliance.

These four items separate a transformer that runs quietly and cool from one that buzzes and trips on over-temperature.

Source UHV-Grade CRGO for Your Project

Tell us your transformer rating, duty (converter / inverter / standard), and efficiency target. We will recommend the correct Hi-B grade and quote coil or pre-cut laminations with a mill certificate.

  • Email: vera.liang@ztwysteel.com
  • Location: Xishan District, Wuxi, Jiangsu, China
  • Supply range: CRGO and CRNGO silicon steel, Hi-B grades, pre-cut laminations
  • Grades: 27Q110, B23R085/B27R095, M4–M6
  • Documentation: MTC with B-H curve, P₁.₇/₅₀, thickness tolerance, coating class

We reply within one working day.