0.35 vs 0.50 mm Non-Oriented Silicon Steel for Motors
When a motor designer or purchaser looks at non-oriented strip, the two gauges that come up most often are 0.50 mm and 0.35 mm. They cover most industrial and efficient motor designs, but they do not sit in the same loss band, and they do not cost the same to stamp and stack. This guide compares the two on core loss, stacking, stamping and price, and sets out which gauge fits which machine. The material is non-oriented electrical steel, the family used in stators, rotors and other rotating parts.
The Two Gauges at a Glance
The grade examples are typical; the loss figure on a real lot comes from its mill certificate at the design induction.
| Gauge | Typical grade band | Typical loss at 1.5 T, 50 Hz | Stacking factor | Common machines |
| 0.50 mm | 50W470, 50W600 class | About 4.70–6.00 W/kg | High, around 0.97 | General-purpose IE2/IE3 motors, pumps, fans, compressors |
| 0.35 mm | 35W300, 35W250 class | About 2.50–3.00 W/kg | Slightly lower | High-efficiency IE3/IE4 motors, servo machines, traction auxiliaries |
The loss gap between the two gauges is real, but it is not the whole story. A 0.35 mm grade and a 0.50 mm grade sit in different parts of the loss range, and within each gauge there are still high and low grades to choose between.
0.50 mm: the General-Purpose Gauge
0.50 mm is the workhorse of the motor industry. At 50 and 60 Hz the eddy-current part of the loss is small enough that the thicker gauge gives away little in efficiency, while keeping the advantages that matter on the production line: fewer laminations per stack, faster punching, wider die tolerance and a lower price per kilogram.
It suits machines where the efficiency class is standard rather than premium, and where the duty cycle does not push temperature to the limit. Pumps, fans, compressors and general-purpose induction motors are the usual home for this gauge. Selecting non-oriented steel for motors works through the efficiency-class side of that choice.
0.35 mm: the Efficiency Gauge
0.35 mm is reached for when the loss budget tightens. Its thinner gauge holds down the eddy-current part of the loss, which is what allows the 35W300 and 35W250 grade band to sit well below the 50W grades on the loss curve. That is the gauge chosen for high-efficiency industrial motors, servo machines and the thinner end of traction auxiliary designs.
The trade is that the same core needs more laminations, the strip needs tighter die clearance to hold the edge, and the material costs more per kilogram. The upgrade pays back where the running hours and efficiency target justify it, not on every general-purpose machine.
Why Thinner Cuts Loss at Motor Frequency
Classical eddy-current loss scales with the square of the gauge. Holding frequency and induction fixed, moving from 0.50 mm to 0.35 mm takes the eddy-current part to roughly half, since (0.35 / 0.50)² ≈ 0.49.
Two qualifications keep this honest. First, the square rule applies to the eddy-current part only; hysteresis loss does not fall with thickness, so total core loss drops by less than the eddy ratio suggests. Second, the comparison holds at the same frequency and induction. At 50 or 60 Hz the gain from 0.35 mm is meaningful but bounded; above that frequency the case for thinner gauge strengthens quickly. How CRNGO grade codes read explains how the loss number in the grade name maps to the test point.
The Cost Side: Stacking, Stamping, Price
Three costs follow every move to the thinner gauge:
- More laminations per stack.The same core height needs more sheets, and the insulation fraction rises, so the stacking factor is slightly lower than 0.50 mm.
- Slower stamping and more burr risk.Thin strip needs controlled die clearance; the line turns out fewer laminations per hour.
- Higher unit price.35 mm carries a premium per kilogram, and scrap from narrow parts adds to it.
The decision therefore runs on total cost of ownership: the thinner gauge earns its premium if the no-load loss saving over running hours covers the material and processing difference. Whether thinner always means lower loss covers the limits of that rule, which apply to motor steel as well.
![]()
When Thickness Is Not the Only Decision
Two other choices sit alongside the gauge, and they can matter more than the 0.35/0.50 split.
- Grade level within the gauge.A 0.50 mm high grade can outperform a 0.35 mm economy grade on loss, so the grade band should be fixed before the gauge is argued over.
- A motor running well above mains frequency moves toward 0.27, 0.20 or thinner, where neither 0.50 nor 0.35 holds the loss down. The EV motor end of that range is covered in the non-oriented steel used for traction motors.
Selection Checklist
- Write down the efficiency class and the maximum no-load loss the stator can accept.
- Note the electrical frequency, not only the shaft speed.
- Fix the grade band from the loss curve at the design induction.
- Choose the gauge that meets that band without over-specifying.
- Confirm the stacking factor the core geometry was calculated on.
- Check the mill certificate loss against the requirement, not the catalogue average.
FAQ
Can 0.35 mm replace 0.50 mm in an existing motor? Usually yes for the material, but the core was stacked to a 0.50 mm factor. Re-stacking in 0.35 mm changes the steel fraction and the number of sheets, so the design should be checked rather than swapped blindly.
Can 0.50 mm replace 0.35 mm? Only if the loss budget allows the higher loss. A machine specified for the 0.35 mm grade band will often run hotter or less efficiently on 0.50 mm.
Does 0.35 mm always give a quieter motor? Lower core loss helps temperature and vibration, but noise also depends on slot design, winding and mechanical balance. The gauge alone does not determine noise.
Which gauge goes into appliance motors? Cost-driven small appliance motors often use 0.50 mm or the thicker 0.65 mm economy grades. 0.35 mm is reserved where the efficiency target calls for it.
Unsure which gauge your motor design needs? Send the rating, efficiency class and frequency to vera.liang@ztwysteel.com, and we will suggest a gauge and grade range before the order is specified.