Industrial Large-Scale Transformer Project

The Tangshan green smart steelmaking upgrading project specified premium oriented silicon steel for 200 MVA electric arc furnace (EAF) transformers and 40 MVA refining furnace transformers. EAF transformers are the toughest service duty in the transformer world. They do not run at steady load like grid transformers. Instead, they absorb repeated short-circuit currents, thermal shocks, and overload cycles as scrap melts down. The CRGO specification for this duty looks different from a standard grid transformer.

Challenge 1: Repeated Short-Circuit Currents

When an arc furnace arc strikes or collapses, the transformer sees a short-circuit current of 2–3 times rated value. That current creates massive electromagnetic forces in the winding and a sudden flux surge in the core. Standard CRGO may tolerate one such event; however, repeated surges over years cause inter-laminar shorting and core loosening.

Consequently, EAF-grade CRGO needs:

  • Higher peak permeability to absorb flux surges without saturation.
  • Stronger inter-laminar coating to resist mechanical vibration.
  • Tighter thickness tolerance so flux distributes evenly across the core stack.

Challenge 2: Continuous Overload and High Ambient Heat

A steel plant workshop runs at 40–50°C ambient. The EAF transformer already runs hot from its own losses. Furthermore, EAF duty cycles demand 110–120% overload for extended periods. Under these conditions, core temperature can reach 110–120°C.

Standard CRGO coating degrades above 100°C over years. EAF-grade cores specify C-4 high-temperature insulation coating that holds up at continuous 120°C operation. This is not optional—it is the difference between a 20-year core and a 10-year core.

EAF transformer core

Challenge 3: Low No-Load Loss Meets High Overload

Grid transformers optimize no-load loss because they run continuously at steady load. EAF transformers, by contrast, spend part of the day idle. Yet when they run, they carry massive overload. The CRGO choice must balance two competing goals:

  • Low no-load loss during idle hours.
  • High permeability margin during overload surges.

Hi-B oriented steel handles both: it cuts no-load loss like a premium grade, and it retains permeability at high flux density where standard CGO saturates.

CRGO and Related Products for Industrial Duty

For heavy industrial transformer and rectifier duty, we supply:

Specify EAF-Grade CRGO in One Line

A complete EAF transformer core order reads: “27Q110 Hi-B, 0.27 mm, C-4 high-temperature coating, stepped-lap mitred cut, P₁.₇/₅₀ ≤ 1.10 W/kg, thickness tolerance ±0.01 mm.” Leave out the coating or the tolerance and the core will not survive furnace duty.

Source CRGO for Your Industrial Transformer

Tell us your transformer rating, duty (EAF, ladle furnace, rectifier), and overload requirement. We will recommend the correct Hi-B grade and quote coil or cut laminations with a mill certificate.

  • Email: vera.liang@ztwysteel.com
  • Location: Xishan District, Wuxi, Jiangsu, China
  • Supply range: CRGO and CRNGO silicon steel, copper cooling tube, nickel alloys
  • Grades: 27Q110/120, B-series Hi-B, M4–M6
  • Documentation: MTC with core loss, permeability, thickness tolerance, and coating class