What magnetic properties should I check before buying grain-oriented silicon steel?

The list looks long, yet most of it is noise. Useful magnetic properties fall into four tiers, and only the first tier belongs on a purchase order. Everything else either supports the design or adds nothing. Jiangsu Zhongtong Weiye Special Steel Co., Ltd. quotes the first tier on every certificate.

Tier A — Facts a Certificate Must Show

Four numbers decide the deal, namely loss at 1.7 T and 50 Hz, B800, gauge, and coating class. Without these, no comparison is possible, since every other figure needs them as context. Consequently, a supplier who omits one of the four has not answered the question.

Four numbers, one specification.

Tier B — Extras Worth Asking For

Loss at 1.5 T and 1.0 T helps, because motors and reactors often run below 1.7 T. The anisotropy ratio also matters, since it tells you what happens across the grain. Stacking factor belongs here too, because it changes the core window.

These extras refine a design, and they rarely change a decision.

Tier C — Data Only a Lab Can Produce

Harmonic loss, 60 Hz curves, and loss at high induction need a proper test bench. An Epstein frame gives standard values, while a single-sheet tester suits production checks. Therefore, ask for the method before you trust a curve.

The method explains the number as much as the material does.

Tier D — Numbers That Impress and Prove Nothing

Some datasheets lead with a percentage, such as “30% lower loss”, and never state the basis. Others show a curve screenshot without axes or a test standard, which cannot be checked. A comparison against an unnamed grade also fails, since the reference is invisible.

Hence a headline without a basis is marketing, not data.

Why the Basis Beats the Value

A 1.10 W/kg value at 1.5 T loses to a 1.20 value at 1.7 T, since induction shifts loss sharply. The lower induction always flatters the sheet. Buyers who compare the digits alone often pick the weaker sheet. Therefore, always pair the value with its flux density and frequency.

Two numbers, or no number.

What B800 Tells You

B800 measures induction at 800 A/m, so it describes magnetisation rather than loss. A high-induction grade reaches about 1.88 T, while a standard oriented grade sits near 1.80 T. Consequently, B800 predicts inrush behaviour and core size, not efficiency.

Loss sets the running cost, and B800 sets the footprint.

The Directional Ratio

Loss across the grain runs two to three times the rolling-direction figure. That ratio matters when a core turns flux at corners or in wound joints. Hence a datasheet with only one direction hides the number your corner actually uses.

Ask for the cross-direction figure on any corner-heavy design.

What a Wrong Choice Costs

A 0.10 W/kg slip on a 1.2 t core equals 120 W at rated flux. Running all year, that becomes about 1,050 kWh, or roughly €105 at €0.10 per unit. Capitalised at €14 per watt, the slip is worth about €1,680.

Therefore, a careless reading of the datasheet carries a real price.

What You Can Check Yourself

Weigh the coil, measure the gauge at ten points, and compare both against the certificate. Then confirm the coating class letter, because the surface carries the interlayer resistance. A short no-load test on a sample core also confirms the loss within a few percent.

Three checks, no laboratory needed.

How to Write the Purchase Line

Write the loss ceiling first, then its basis, then the frequency. Add B800 if the design is compact, and add the coating class for the process. Finish with the gauge tolerance, since stacking depends on it.

One line, five clauses, no ambiguity.

Four Red Flags in a Datasheet

Watch for a loss value without flux density, and watch for “typical” values used as guarantees. Also flag a grade code that matches no published standard, and flag a certificate that lists no test method.

Each flag points to a supplier who cannot be audited.

Where Suppliers Differ Most

Suppliers differ on test method, on sampling, and on how they state direction. Some quote a batch average, which looks better than a maximum. Others omit the cross-direction figure, because it is unattractive.

Those three gaps explain most price differences.

Related Reading

Our gauge range is listed in the thickness note. Coating classes are explained in the coating note.

Magnetic properties test sheet showing loss at 1.7 T and B800 for oriented steel

Frequently Asked Questions

Which number matters most?

Loss at 1.7 T and 50 Hz, since it drives no-load cost.

Is B800 a loss value?

No, it measures induction at a fixed magnetising current.

Do I need the cross-direction figure?

Yes, if your core has corners or wound joints.

Can a mill guarantee a typical value?

Only a maximum is enforceable, so insist on that.

Is an Epstein test still valid?

Yes, and it remains the reference method for comparison.

What We Do Not Do

We do not run Epstein tests ourselves, since the mill certifies the figures. We do not convert values across bases without stating the conversion. Nor do we compare a grade against an unnamed rival.

Those limits keep the data comparable.

Specify Your Order

First, state the loss ceiling and its basis. Second, give the gauge and width. Then name the coating class, so the certificate matches your drawing.

M5 Grain Oriented Electrical Steel covers the mainstream loss classes. M4 Grain Oriented Electrical Steel serves thicker builds. Quotes return within one working day.

  • Email: vera.liang@ztwysteel.com
  • Location: Xishan District, Wuxi, Jiangsu, China
  • Supply range: CRGO 0.23–0.35 mm, 23Q085 to 35Q150, coating C5 or C6
  • Slitting: 20–1250 mm, ±0.05 mm, burr under 0.02 mm
  • Documentation: MTC EN 10204 3.1, loss and B800 stated per coil