What is the typical core loss of M15 non-oriented electrical steel?
The headline for M15 is 1.5 W/lb, measured at 1.5 T and 60 Hz. That figure is a core loss of M15 ceiling, not an average. Converted, it equals about 3.31 W/kg. Typical production runs a little lower, and a 50 Hz basis lowers it again. Jiangsu Zhongtong Weiye Special Steel Co., Ltd. quotes both bases on request.
The Headline Number
US non-oriented codes state loss in watts per pound, since their home market runs at 60 Hz. M15 therefore promises no more than 1.5 W/lb at 1.5 T. Multiplying by 2.2046 converts it to 3.31 W/kg. Hence the code digit is a limit, not a centre value.
One figure, one basis.
Question 1 — Which Frequency?
In practice, frequency changes the answer more than any grade choice does. Hysteresis scales with frequency, while eddy loss scales with its square. Applying that split to the 60 Hz value leaves roughly 2.57 W/kg at 50 Hz. Consequently, the same coil reads lower on a European supply.
Question 2 — Which Induction?
Most motors run below 1.5 T in the yoke, so the 1.5 T figure rarely applies. Loss falls steeply as induction drops, since both components follow a power curve. Consequently, at 1.0 T the same sheet lands near 1.49 W/kg. Therefore, a datasheet alone cannot predict your core.
Question 3 — Maximum or Typical?
A mill certifies a maximum, because that is the enforceable number. Typical coils still land between 1.3 and 1.4 W/lb, since production centres on the middle of the band. That converts to 2.87 to 3.09 W/kg at 60 Hz. Hence a buyer who plans on typical values carries a hidden risk.
Three questions, one useful number.
What Buyers Usually Ask For
Most inquiries name a loss class rather than a frequency. In that case, we ask two questions before quoting, so the basis stays attached. Then we send the coil certificate, because the mill’s number carries more weight than ours. Most mills answer within a day in practice, since the mill holds the data.
The Four Readings Side by Side
- 3.31 W/kg — maximum, 1.5 T, 60 Hz
- 2.57 W/kg — maximum, 1.5 T, 50 Hz
- 2.31 W/kg — typical, 1.5 T, 50 Hz
- 1.49 W/kg — maximum, 1.0 T, 60 Hz
Each row answers a different question, so quote the row you mean.
Why Your Motor Sees Another Number
In a real core, stator flux varies across the tooth, so loss varies with radius. Meanwhile, PWM drives add harmonics, and those losses sit outside any sinusoidal rating. Temperature also shifts resistivity, which trims eddy loss slightly. Therefore, the certificate is a reference point, not a prediction. That is why a wound-core test beats a catalogue comparison. The rated figure remains the design anchor, although a wound test qualifies it.
Where the Number Comes From in Testing
An Epstein frame magnetises a standard square stack of strips, following IEC 60404-2. Because the sample is standardised, mills can compare grades across plants. Also, the sample weight is fixed, so values scale consistently. Therefore the published figure rests on a repeatable setup, not on one coil.
What a Certificate Should State
Before you compare anything, ask for loss at a stated induction, a stated frequency, and a stated test method. The Epstein frame remains the reference, while a single-sheet tester suits production checks. Then ask whether the figure is a maximum or an average. Without those four items, a number cannot be audited.
A Note on 60 Hz Markets
North American buyers keep the 60 Hz basis, so their catalogue numbers look higher than European ones. In fact, the same sheet serves both markets, and only the test frequency moved. Hence 3.31 W/kg can look alarming beside 2.57 W/kg.
Gauge and Silicon Behind the Number
M15 usually arrives near 0.35 mm, since that gauge balances stacking against eddy loss. Silicon sits in the 2.5% to 3.0% range. Because a thinner path cuts eddy loss, the same texture would read lower at a smaller gauge. More silicon would lower it again. Consequently, the code hides a family of coils that differ in both.
How to Sanity-Check a Claim
First, convert the claim with 2.2046, then check the frequency. If a supplier quotes 2.6 W/kg without naming 50 Hz, the basis is missing. Similarly, a 1.5 W/kg claim usually hides a 1.0 T basis. Two arithmetic checks catch most errors, so run both before you sign.
Where M15 Sits Among Neighbours
M12 reads lower, since its digit is 1.2 W/lb, and M19 reads higher. The ladder is linear in the code, although gauge and silicon shift underneath it. A full grade palette sits behind those six digits. Therefore, compare certificates, not neighbouring code digits.
Related Reading
The M12 comparison is covered in the M12 note, and the wider grade list appears in the NGO grades note. Family background sits in the NGO primer.

Frequently Asked Questions
No, it is the maximum at 60 Hz.
About 2.3 W/kg at 1.5 T.
Yes, thinner sheet reads lower at the same texture.
Because only a maximum can be enforced.
Yes, if the test bench supports both.
What We Do Not Do
We do not test coils in-house, since mills certify them. We do not convert a figure without stating the basis. Nor do we quote a typical value as a guarantee.
Those limits keep the number usable.
Specify Your Order
First, state the induction and frequency you design for. Second, give gauge and width. Then confirm whether you need a maximum or an average on the certificate.
M36 Non-Oriented Electrical Steel covers heavier motor duty. M19 Non-Oriented Electrical Steel suits standard frames, so a buyer can pair it with M15. Reactor Core Lamination serves gapped cores. Quotes return within one working day.
- Email: vera.liang@ztwysteel.com
- Location: Xishan District, Wuxi, Jiangsu, China
- Supply range: CRNGO 0.35–1.00 mm, 35W270 to 65W800
- Slitting: 20–1250 mm, ±0.05 mm, burr under 0.02 mm
- Documentation: MTC EN 10204 3.1, loss with induction and frequency stated