What is the maximum coil width available for grain-oriented electrical steel?
The maximum coil width we can deliver is 1250 mm, cut from a master coil of the same width. Above that figure, the answer depends on the mill rather than on us. Consequently, 1250 mm acts as a practical ceiling for most transformer orders. Jiangsu Zhongtong Weiye Special Steel Co., Ltd. slits to any width from 20 mm upward.
The Short Answer
One number answers the question, namely 1250 mm. That is both the master width we buy and the widest strip we can slit. Below it, every width is available in 0.05 mm steps. Therefore, a customer asking for more must change the supply route, not the request.
Ceiling 1 — The Mill Master
Master coils arrive at 1250 mm, which is the standard width for oriented sheet. Some mills also roll 1000 mm and 1200 mm, so stock varies by campaign. Hence the master sets the first hard limit, since we cannot add steel that was never rolled.
Ceiling 2 — Our Slitter
Our line takes masters up to 1250 mm and cuts strips from 20 mm upward. Width tolerance holds at ±0.05 mm, and burr stays under 0.02 mm. Consequently, the slitter rarely limits the design, although very narrow slits consume yield.
Ceiling 3 — Your Decoiler
Your own line sets the next limit, because a decoiler accepts a maximum width and a maximum coil weight. Standard bore is 508 mm, and coil weight often caps near 5 t. Therefore, a wide coil can still be rejected by the machine that must unwind it.
Ask your line builder before you order a full-width coil.
Ceiling 4 — Freight and Packing
Coils travel eye-to-sky in containers, so the outer diameter decides how many fit. A 20ft box carries 25–28 t, although coil diameter often limits the count before weight does. Moreover, a 1250 mm coil needs a crate wide enough to protect the edges.
Hence the shipping plan can reduce the usable width.
Why Wider Is Not Automatically Better
Wider strip reduces the number of cuts, so yield improves. Yet a wide coil also amplifies camber, since any edge wave runs the full length. Consequently, a 1250 mm coil demands flatter master stock than a 300 mm coil does.
Width and flatness trade against each other.
Why Very Narrow Wastes Yield
Cutting four 300 mm strips from a 1250 mm master leaves 50 mm of trim. That trim returns as scrap value, so yield lands near 96%. Cutting twelve 100 mm strips leaves the same 50 mm, while slitting time rises threefold.
Therefore, the yield arithmetic favours widths that divide neatly.
What Happens Above 1250 mm
Two routes exist, and neither is routine. A mill can roll a wider master for a large programme, although few lines offer that option. Alternatively, a customer can weld or stagger narrower coils, which usually defeats the purpose.
Consequently, designs above 1250 mm should be revisited, not ordered.
A Note on Coil Diameter
Width is only one dimension, since diameter decides how the coil sits on the decoiler. A 1250 mm coil of 0.35 mm sheet grows heavy quickly, so diameter follows weight. Hence a wide coil often ships as two smaller coils.
How to Specify Width
Give the finished width, the tolerance, and the direction of measurement. State whether the width applies before or after coating, since coating adds a few micrometres. Then confirm the coil weight and bore, so the decoiler accepts the coil.
Three lines, and the order is unambiguous.
What to Do If the Drawing Says 1300 mm
Revisit the limb design first, since a smaller core step may fit the same window. Or accept a longitudinal weld, although the joint raises loss locally. Otherwise, ask a mill for a programme, and expect a long lead.
Common Widths We See
Transformer shops order 300, 400, 500, and 600 mm most often, since those match common limb sizes. Motor shops order 400 to 1250 mm for continuous punching lines. Repair shops order narrow strips, often 100 to 200 mm.
Those four bands cover most of the demand.
Related Reading
Gauge options are listed in the thickness note. How the strip becomes a core is described in the core-making note.

Frequently Asked Questions
At our slitter yes, although mills can roll wider on a programme.
No, since no master of that width is available to us.
20 mm, with burr held under 0.02 mm.
Not directly, although edge burr and stress do.
The line holds ±0.05 mm, which is tighter than most drawings need.
What We Do Not Do
We do not roll masters or weld coils into wider strip. We do not guarantee flatness beyond the mill’s own limit. Nor do we quote a width we cannot source.
Those limits keep the answer firm.
Specify Your Order
First, state the finished width and tolerance. Second, give the gauge and the loss ceiling. Then confirm coil weight and bore, so we can plan the slit and the packing.
M5 Grain Oriented Electrical Steel covers mainstream transformer widths. M4 Grain Oriented Electrical Steel serves thicker builds and repair work. Quotes return within one working day.
- Email: vera.liang@ztwysteel.com
- Location: Xishan District, Wuxi, Jiangsu, China
- Supply range: CRGO 0.23–0.35 mm, 23Q085 to 35Q150, coating C5 or C6
- Slitting: 20–1250 mm, ±0.05 mm, burr under 0.02 mm