What is the difference between 27QG110 and 27QG120 silicon steel?
The gap between 27QG110 and 27QG120 is 0.10 W/kg, and nothing else in the specification changes. Both are 0.27 mm high-induction grain-oriented strip with the same texture and coating. Consequently, the choice reduces to one number and its payback. Jiangsu Zhongtong Weiye Special Steel Co., Ltd. supplies both grades from stock or programme.
The Only Difference Between 27QG110 and 27QG120
The trailing digits set the ceiling at 1.7 T and 50 Hz. Hence 110 means 1.10 W/kg, and 120 means 1.20 W/kg. Both figures are maxima, not averages. Therefore, the comparison stays honest only when both arrive with the same basis.
How the Two Codes Are Written
Chinese practice writes the gauge first, then Q for oriented and G for high induction. European practice instead writes 27P110, so the same sheet carries two names. Consequently, an offer may arrive under either convention, and the loss figure still decides.
What Stays Identical
Gauge stays at 0.27 mm, which fixes eddy behaviour and stacking. Texture stays Goss-oriented, so cross-direction loss rises two to three times in both. B800 stays near 1.88 T, because the G suffix applies to both. Moreover, coating class and thickness tolerance usually match.
Hence one variable moves, and five hold still.
Ledger 1 — Annual Energy
Take a 1000 kVA unit with a 1.2 t core, which is a typical build. The 0.10 W/kg step equals 120 W at rated flux, since 0.10 W/kg times 1200 kg gives that figure. Running continuously, 120 W becomes about 1,050 kWh per year.
One decimal, and a kilowatt-hour figure appears.
Ledger 2 — Lifetime Value
At €0.10 per kWh, the annual gap is roughly €105. Capitalised at about €14 per watt, 120 W carries a lifetime value near €1,680. Therefore, the lower-loss grade pays for itself if the premium stays under that figure.
That is the whole negotiating position.
Ledger 3 — Price Premium
A 10-point step usually adds a few percent per ton, although mill campaigns vary. On a 1.2 t core, that premium lands well below the €1,680 value. Consequently, the arithmetic favours 27QG110 for continuously energised units.
Ledger 4 — Core Temperature
The 120 W difference becomes heat inside the core, so the hotter grade runs a few kelvin warmer. Insulation life halves for roughly every 6 K rise, since ageing follows temperature. Hence a cooler core also buys maintenance margin, not just energy.
Ledger 5 — Supply Risk
27QG120 is the volume grade, so stock and slit widths are wider. 27QG110 sits one step lower, which narrows availability and lengthens campaigns. Therefore, an urgent build may have to accept 120 even when 110 would pay better.
A Worked Comparison for a 630 kVA Unit
Assume a 0.75 t core, which suits a 630 kVA build. The gap then equals 75 W, since 0.10 W/kg times 750 kg gives that figure. Capitalised, 75 W is worth about €1,050, while the price step may reach €600. So the upgrade still wins, although the margin narrows.
How to Test the Claim Yourself
Ask for both certificates, then compare the loss at one basis. Ask for the coil weight, since the annual figure needs it. Finally, multiply by your own tariff, because €0.10 is only an example.
Which Buyer Takes Which
Continuous-duty transformers above 800 kVA should take 110, since the hours justify the premium. Intermittent units below 400 kVA should take 120, because the saving never accumulates. Repair jobs should take whatever the certificate allows, since matching the original matters more.
Three profiles, three answers.
What a Small Buyer Should Ignore
Ignore the decimal when the unit runs under 2000 hours a year. Ignore it too when the core weighs under 300 kg. Hence the grade choice becomes a supply question, not a loss question.
Where the Two Grades Converge
Below about 400 kVA the loss gap is trivial, since the core weighs little. Above about 2000 kVA both grades look expensive next to 0.23 mm sheet. Consequently, the real window is the middle band, roughly 500 to 1500 kVA.
When to Ask for a Third Grade
Ask for 27QG100 when the unit runs continuously and the core exceeds 1 t. Ask for 27QG130 when price dominates, since it still meets most distribution duties. Then compare all three on one tariff, because a single step can mislead.
Related Reading
The single-value basis for the higher grade appears in the 27QG120 loss note. Gauge tiers and stock coverage sit in the oriented grades note.

Frequently Asked Questions
Yes, and every other property matches within normal tolerance.
27QG120, since it moves in larger volumes.
Only on units that run most of the year.
Yes, although each lot needs its own certificate.
Somewhat, because mills schedule it less often.
What We Do Not Do
We do not blend certificates across two grades. We do not promise a loss figure without a basis. Nor do we claim a payback we cannot support with your duty cycle.
Those limits keep the comparison usable.
Specify Your Order
First, state annual running hours. Second, name the W/kg ceiling. Then give the slit width, so we can confirm which grade ships first.
M5 Grain Oriented Electrical Steel covers this 0.27 mm band, and M4 Grain Oriented Electrical Steel covers thicker builds. Quotes return within one working day.
- Email: vera.liang@ztwysteel.com
- Location: Xishan District, Wuxi, Jiangsu, China
- Supply range: CRGO 0.23–0.35 mm, 23Q085 to 35Q150, coating C5 or C6
- Slitting: 20–1250 mm, ±0.05 mm, burr under 0.02 mm
- Documentation: MTC EN 10204 3.1, loss data per ASTM A343 / IEC 60404-2