{"id":4216,"date":"2026-09-20T09:31:24","date_gmt":"2026-09-20T09:31:24","guid":{"rendered":"https:\/\/www.jycomat.com\/?p=4216"},"modified":"2026-09-20T09:31:24","modified_gmt":"2026-09-20T09:31:24","slug":"can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers","status":"publish","type":"post","link":"https:\/\/www.jycomat.com\/pt\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/","title":{"rendered":"Can ordinary transformer steel be applied for high-frequency transformers"},"content":{"rendered":"<p><html><body><\/p>\n<p><strong>Can Ordinary Transformer Steel Be Applied for High-Frequency Transformers?<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp\"\/><\/p>\n<p>Engineers often ask if standard transformer steel works in high-frequency designs. The short answer is no for most cases. Ordinary steel suits low-frequency power grids. High-frequency transformers need different core materials. This mismatch causes heat, loss, and poor performance.<\/p>\n<p><strong>Why Ordinary Transformer Steel Fails at High Frequencies<\/strong><\/p>\n<p>Ordinary transformer steel contains silicon and iron. It has high magnetic permeability. However, its resistivity stays low. At 50 or 60 Hz, eddy currents remain small. Yet, at 20 kHz or higher, eddy currents grow fast. These currents create strong heat. They also waste energy. Consequently, the core overheats. The transformer may fail soon after.<\/p>\n<p><strong>The Role of Eddy Current and Hysteresis Losses<\/strong><\/p>\n<p>Eddy current loss rises with frequency squared. Hysteresis loss also increases with frequency. Ordinary steel has thick laminations. These laminations cannot stop high-frequency eddy currents. As a result, core loss becomes huge. Efficiency drops sharply. The transformer cannot deliver stable power. So, ordinary steel is a poor choice for high-frequency use.<\/p>\n<p><strong>What Materials Work Better for High-Frequency Transformers<\/strong><\/p>\n<p>Ferrite cores dominate high-frequency designs. Ferrite has high resistivity. It reduces eddy currents to a low level. Powdered iron cores also work well. They offer stable performance up to hundreds of kHz. Nanocrystalline cores serve advanced applications. Each material handles high frequency with low loss. They cost more than ordinary steel. Yet, they save energy and improve reliability.<\/p>\n<p><strong>When Ordinary Steel Might Still Be Considered<\/strong><\/p>\n<p>A few low-frequency high-power cases might use ordinary steel. For example, some 400 Hz transformers use thin <a href=\"https:\/\/www.jycomat.com\/pt\/aco-ao-silicio\/\" data-internallinksmanager029f6b8e52c=\"1\" title=\"A\u00e7o ao sil\u00edcio\">a\u00e7o ao sil\u00edcio<\/a>. But even then, laminations must be very thin. This approach only works at the low end of high frequency. Above a few kHz, ordinary steel becomes impractical. So, the answer remains no for true high-frequency transformers.<\/p>\n<p><strong>Key Design Trade-Offs and Practical Advice<\/strong><\/p>\n<p>Designers must balance cost, size, and efficiency. Ordinary steel is cheap and strong. But it fails at high frequency. Ferrite costs more but cuts loss. Therefore, engineers choose ferrite for switch-mode supplies. They choose powdered iron for filters. They avoid ordinary steel above 1 kHz. This rule keeps designs safe and efficient.<\/p>\n<p><strong>Conclusion: A Clear Material Boundary<\/strong><\/p>\n<p>Ordinary transformer steel cannot serve high-frequency transformers well. Its low resistivity causes excessive eddy currents. Those currents create heat and waste power. Better materials like ferrite and powdered iron solve this problem. For any high-frequency application, engineers should select the right core. This choice ensures long life, high efficiency, and reliable operation. In short, ordinary steel belongs to low-frequency duty only.<\/p>\n<p><\/body><\/html><\/p>","protected":false},"excerpt":{"rendered":"<p>Can Ordinary Transformer Steel Be Applied for High-Frequency Transformers? Engineers often ask if standard transformer steel works in high-frequency designs. The short answer is no for most cases. Ordinary steel suits low-frequency power grids. High-frequency transformers need different core materials. This mismatch causes heat, loss, and poor performance. Why Ordinary Transformer Steel Fails at High [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4217,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","footnotes":""},"categories":[5],"tags":[61,1507,977,1506,69],"class_list":["post-4216","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-eddy-current-loss","tag-ferrite-cores","tag-high-frequency-transformers","tag-ordinary-transformer-steel","tag-transformer-core-material"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Can ordinary transformer steel be applied for high-frequency transformers - Zhongtongweiye<\/title>\n<meta name=\"description\" content=\"Can ordinary transformer steel be applied for high-frequency transformers Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.jycomat.com\/pt\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Can ordinary transformer steel be applied for high-frequency transformers - Zhongtongweiye\" \/>\n<meta property=\"og:description\" content=\"Can ordinary transformer steel be applied for high-frequency transformers Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.jycomat.com\/pt\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/\" \/>\n<meta property=\"og:site_name\" content=\"Silicon Steel - Zhongtongweiye\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-20T09:31:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"801\" \/>\n\t<meta property=\"og:image:height\" content=\"803\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"adminwxzd\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"adminwxzd\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/\"},\"author\":{\"name\":\"adminwxzd\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/person\\\/2d5d62a164d46f464cb79f7e71f46f2d\"},\"headline\":\"Can ordinary transformer steel be applied for high-frequency transformers\",\"datePublished\":\"2026-09-20T09:31:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/\"},\"wordCount\":425,\"publisher\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Mold-Steel-6-4.webp\",\"keywords\":[\"eddy current loss\",\"ferrite cores\",\"high-frequency transformers\",\"ordinary transformer steel\",\"transformer core material\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"pt-PT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/\",\"name\":\"Can ordinary transformer steel be applied for high-frequency transformers - Zhongtongweiye\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Mold-Steel-6-4.webp\",\"datePublished\":\"2026-09-20T09:31:24+00:00\",\"description\":\"Can ordinary transformer steel be applied for high-frequency transformers Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Mold-Steel-6-4.webp\",\"contentUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Mold-Steel-6-4.webp\",\"width\":801,\"height\":803},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.jycomat.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Can ordinary transformer steel be applied for high-frequency transformers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#website\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/\",\"name\":\"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#organization\",\"name\":\"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/cropped-favicon.webp\",\"contentUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/cropped-favicon.webp\",\"width\":512,\"height\":512,\"caption\":\"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/person\\\/2d5d62a164d46f464cb79f7e71f46f2d\",\"name\":\"adminwxzd\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g\",\"caption\":\"adminwxzd\"},\"sameAs\":[\"https:\\\/\\\/www.jycomat.com\"],\"url\":\"https:\\\/\\\/www.jycomat.com\\\/pt\\\/author\\\/adminwxzd\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Can ordinary transformer steel be applied for high-frequency transformers - Zhongtongweiye","description":"Can ordinary transformer steel be applied for high-frequency transformers Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.jycomat.com\/pt\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/","og_locale":"pt_PT","og_type":"article","og_title":"Can ordinary transformer steel be applied for high-frequency transformers - Zhongtongweiye","og_description":"Can ordinary transformer steel be applied for high-frequency transformers Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.","og_url":"https:\/\/www.jycomat.com\/pt\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/","og_site_name":"Silicon Steel - Zhongtongweiye","article_published_time":"2026-09-20T09:31:24+00:00","og_image":[{"width":801,"height":803,"url":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp","type":"image\/webp"}],"author":"adminwxzd","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"adminwxzd","Tempo estimado de leitura":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/#article","isPartOf":{"@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/"},"author":{"name":"adminwxzd","@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/person\/2d5d62a164d46f464cb79f7e71f46f2d"},"headline":"Can ordinary transformer steel be applied for high-frequency transformers","datePublished":"2026-09-20T09:31:24+00:00","mainEntityOfPage":{"@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/"},"wordCount":425,"publisher":{"@id":"https:\/\/www.jycomat.com\/bg\/#organization"},"image":{"@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp","keywords":["eddy current loss","ferrite cores","high-frequency transformers","ordinary transformer steel","transformer core material"],"articleSection":["Blog"],"inLanguage":"pt-PT"},{"@type":"WebPage","@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/","url":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/","name":"Can ordinary transformer steel be applied for high-frequency transformers - Zhongtongweiye","isPartOf":{"@id":"https:\/\/www.jycomat.com\/bg\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/#primaryimage"},"image":{"@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp","datePublished":"2026-09-20T09:31:24+00:00","description":"Can ordinary transformer steel be applied for high-frequency transformers Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.","breadcrumb":{"@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/#primaryimage","url":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp","contentUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp","width":801,"height":803},{"@type":"BreadcrumbList","@id":"https:\/\/www.jycomat.com\/can-ordinary-transformer-steel-be-applied-for-high-frequency-transformers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.jycomat.com\/"},{"@type":"ListItem","position":2,"name":"Can ordinary transformer steel be applied for high-frequency transformers"}]},{"@type":"WebSite","@id":"https:\/\/www.jycomat.com\/bg\/#website","url":"https:\/\/www.jycomat.com\/bg\/","name":"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye","description":"","publisher":{"@id":"https:\/\/www.jycomat.com\/bg\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.jycomat.com\/bg\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/www.jycomat.com\/bg\/#organization","name":"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye","url":"https:\/\/www.jycomat.com\/bg\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/logo\/image\/","url":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/08\/cropped-favicon.webp","contentUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/08\/cropped-favicon.webp","width":512,"height":512,"caption":"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye"},"image":{"@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/person\/2d5d62a164d46f464cb79f7e71f46f2d","name":"adminwxzd","image":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/secure.gravatar.com\/avatar\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g","caption":"adminwxzd"},"sameAs":["https:\/\/www.jycomat.com"],"url":"https:\/\/www.jycomat.com\/pt\/author\/adminwxzd\/"}]}},"uagb_featured_image_src":{"full":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp",801,803,false],"thumbnail":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4-300x301.webp",300,301,true],"medium":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4-500x501.webp",500,501,true],"medium_large":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4-768x770.webp",768,770,true],"large":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp",801,803,false],"1536x1536":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp",801,803,false],"2048x2048":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4.webp",801,803,false],"trp-custom-language-flag":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-6-4-12x12.webp",12,12,true]},"uagb_author_info":{"display_name":"adminwxzd","author_link":"https:\/\/www.jycomat.com\/pt\/author\/adminwxzd\/"},"uagb_comment_info":0,"uagb_excerpt":"Can Ordinary Transformer Steel Be Applied for High-Frequency Transformers? Engineers often ask if standard transformer steel works in high-frequency designs. The short answer is no for most cases. Ordinary steel suits low-frequency power grids. High-frequency transformers need different core materials. This mismatch causes heat, loss, and poor performance. Why Ordinary Transformer Steel Fails at High&hellip;","_links":{"self":[{"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/posts\/4216","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/comments?post=4216"}],"version-history":[{"count":1,"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/posts\/4216\/revisions"}],"predecessor-version":[{"id":4223,"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/posts\/4216\/revisions\/4223"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/media\/4217"}],"wp:attachment":[{"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/media?parent=4216"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/categories?post=4216"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jycomat.com\/pt\/wp-json\/wp\/v2\/tags?post=4216"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}