{"id":3566,"date":"2026-09-20T08:52:17","date_gmt":"2026-09-20T08:52:17","guid":{"rendered":"https:\/\/www.jycomat.com\/?p=3566"},"modified":"2026-09-20T08:52:17","modified_gmt":"2026-09-20T08:52:17","slug":"why-an-insulating-coating-is-mandatory-for-transformer-steel","status":"publish","type":"post","link":"https:\/\/www.jycomat.com\/ms\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/","title":{"rendered":"Why an insulating coating is mandatory for transformer steel"},"content":{"rendered":"<p><html><body><\/p>\n<p><strong>Why an Insulating Coating Is Mandatory for Transformer Steel<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp\"\/><\/p>\n<p>Transformer steel sits at the heart of every electrical grid. It carries magnetic flux with very low loss. However, bare steel alone cannot do this job well. An insulating coating is therefore mandatory. This thin layer solves several critical problems at once. It also protects the core for decades of nonstop service.<\/p>\n<p><strong>The Problem With Conductive Cores<\/strong><\/p>\n<p>Transformer steel conducts electricity quite easily. When magnetic flux changes, it induces voltage inside the core. That voltage drives unwanted circulating currents. These currents are called eddy currents. They flow from one lamination to the next. As a result, they produce heat and waste energy. A single solid core would suffer enormous losses. In large power transformers, those losses could reach dangerous levels. The steel could overheat and fail. Insulation stops this path before it starts.<\/p>\n<p><strong>How the Coating Blocks Eddy Currents<\/strong><\/p>\n<p>An insulating coating creates a barrier between thin steel sheets. Each sheet is called a lamination. The coating resists current flow across the stack. Consequently, eddy currents stay trapped inside each sheet. Their loops become very small. Small loops mean much lower loss. The coating must survive high temperatures and pressure. It also must resist mechanical stress during winding. Common coatings include ceramic, phosphate, and enamel layers. Each type offers specific benefits for different transformer designs.<\/p>\n<p><strong>Reducing Core Loss and Heat<\/strong><\/p>\n<p>Core loss has two main parts. Hysteresis loss comes from magnetic reversal. Eddy loss comes from circulating currents. Insulation directly targets the second part. Without it, eddy loss can dominate total loss. The core would run much hotter. Cooling systems would need to be larger. Operating costs would rise every hour. A proper coating cuts eddy loss by a huge margin. This improvement raises efficiency and lowers temperature. It also extends the life of the insulation system around the core.<\/p>\n<p><strong>Protecting Lamination Surfaces<\/strong><\/p>\n<p>Steel surfaces can oxidize or corrode over time. Moisture and chemicals may attack bare metal. An insulating coating seals the surface from these threats. It prevents rust and surface damage. This protection keeps magnetic properties stable. It also reduces the risk of short circuits between laminations. Even a small short can create a hot spot. That spot may spread and damage the whole core. Coating integrity is therefore a key quality check in production.<\/p>\n<p><strong>Mechanical and Manufacturing Benefits<\/strong><\/p>\n<p>The coating also helps during manufacturing. Laminations must be stacked tightly and precisely. A smooth coating reduces friction between sheets. It allows clean handling and cutting. It also provides some edge protection. Burrs can pierce insulation and cause faults. A good coating resists that piercing. Furthermore, the coating helps bond layers in some designs. This bonding adds mechanical strength to the core. The core then resists vibration and noise during operation.<\/p>\n<p><strong>Meeting Efficiency Standards<\/strong><\/p>\n<p>Modern energy rules demand high transformer efficiency. Utilities and industries must reduce wasted power. An insulating coating is a direct way to meet those rules. It lowers no-load loss significantly. It also supports higher flux density operation. Designers can then use less steel for the same power. That saving reduces weight and cost. At the same time, the transformer runs cooler and quieter. These gains matter for both small distribution units and large grid transformers.<\/p>\n<p><strong>Consequences of a Missing Coating<\/strong><\/p>\n<p>If the coating is absent or damaged, problems appear quickly. Eddy currents rise and heat builds up. Insulation paper may degrade faster. Short circuits between laminations become likely. The core may develop hot spots and local melting. Efficiency drops and operating costs climb. In severe cases, the transformer fails early. Repair is expensive and downtime is costly. Therefore, the coating is not optional. It is a mandatory part of reliable transformer design.<\/p>\n<p><strong>Conclusion: A Small Layer With Huge Value<\/strong><\/p>\n<p>An insulating coating on transformer steel is mandatory for good reason. It controls eddy currents, cuts losses, and limits heat. It protects against corrosion and mechanical damage. It also helps meet efficiency standards and extend service life. This thin layer costs little compared to its benefits. For any transformer, it ensures stable and efficient performance. Without it, the core cannot serve the grid safely. With it, the transformer delivers power reliably for many years.<\/p>\n<p><\/body><\/html><\/p>","protected":false},"excerpt":{"rendered":"<p>Why an Insulating Coating Is Mandatory for Transformer Steel Transformer steel sits at the heart of every electrical grid. It carries magnetic flux with very low loss. However, bare steel alone cannot do this job well. An insulating coating is therefore mandatory. This thin layer solves several critical problems at once. It also protects the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3567,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","footnotes":""},"categories":[5],"tags":[46,115,56,62,1295,1274,377,317,313,852],"class_list":["post-3566","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-core-loss","tag-eddy-currents","tag-electrical-steel","tag-hysteresis-loss","tag-insulating-coating","tag-lamination","tag-magnetic-flux","tag-power-transformer","tag-transformer-efficiency","tag-transformer-steel"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Why an insulating coating is mandatory for transformer steel - Zhongtongweiye<\/title>\n<meta name=\"description\" content=\"Why an insulating coating is mandatory for transformer steel Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.jycomat.com\/ms\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/\" \/>\n<meta property=\"og:locale\" content=\"ms_MY\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why an insulating coating is mandatory for transformer steel - Zhongtongweiye\" \/>\n<meta property=\"og:description\" content=\"Why an insulating coating is mandatory for transformer steel Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.jycomat.com\/ms\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/\" \/>\n<meta property=\"og:site_name\" content=\"Silicon Steel - Zhongtongweiye\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-20T08:52:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"adminwxzd\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"adminwxzd\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/\"},\"author\":{\"name\":\"adminwxzd\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/person\\\/2d5d62a164d46f464cb79f7e71f46f2d\"},\"headline\":\"Why an insulating coating is mandatory for transformer steel\",\"datePublished\":\"2026-09-20T08:52:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/\"},\"wordCount\":706,\"publisher\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Non-Oriented-Electrical-Steel-8-3.webp\",\"keywords\":[\"core loss\",\"eddy currents\",\"electrical steel\",\"hysteresis loss\",\"insulating coating\",\"lamination\",\"magnetic flux\",\"power transformer\",\"transformer efficiency\",\"transformer steel\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"ms-MY\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/\",\"name\":\"Why an insulating coating is mandatory for transformer steel - Zhongtongweiye\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Non-Oriented-Electrical-Steel-8-3.webp\",\"datePublished\":\"2026-09-20T08:52:17+00:00\",\"description\":\"Why an insulating coating is mandatory for transformer steel Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/#breadcrumb\"},\"inLanguage\":\"ms-MY\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ms-MY\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Non-Oriented-Electrical-Steel-8-3.webp\",\"contentUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Non-Oriented-Electrical-Steel-8-3.webp\",\"width\":800,\"height\":800},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/why-an-insulating-coating-is-mandatory-for-transformer-steel\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.jycomat.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why an insulating coating is mandatory for transformer steel\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#website\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/\",\"name\":\"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ms-MY\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#organization\",\"name\":\"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ms-MY\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/cropped-favicon.webp\",\"contentUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/cropped-favicon.webp\",\"width\":512,\"height\":512,\"caption\":\"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/person\\\/2d5d62a164d46f464cb79f7e71f46f2d\",\"name\":\"adminwxzd\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ms-MY\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g\",\"caption\":\"adminwxzd\"},\"sameAs\":[\"https:\\\/\\\/www.jycomat.com\"],\"url\":\"https:\\\/\\\/www.jycomat.com\\\/ms\\\/author\\\/adminwxzd\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Why an insulating coating is mandatory for transformer steel - Zhongtongweiye","description":"Why an insulating coating is mandatory for transformer steel Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.jycomat.com\/ms\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/","og_locale":"ms_MY","og_type":"article","og_title":"Why an insulating coating is mandatory for transformer steel - Zhongtongweiye","og_description":"Why an insulating coating is mandatory for transformer steel Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.","og_url":"https:\/\/www.jycomat.com\/ms\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/","og_site_name":"Silicon Steel - Zhongtongweiye","article_published_time":"2026-09-20T08:52:17+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp","type":"image\/webp"}],"author":"adminwxzd","twitter_card":"summary_large_image","twitter_misc":{"Written by":"adminwxzd","Est. reading time":"3 minit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/#article","isPartOf":{"@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/"},"author":{"name":"adminwxzd","@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/person\/2d5d62a164d46f464cb79f7e71f46f2d"},"headline":"Why an insulating coating is mandatory for transformer steel","datePublished":"2026-09-20T08:52:17+00:00","mainEntityOfPage":{"@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/"},"wordCount":706,"publisher":{"@id":"https:\/\/www.jycomat.com\/bg\/#organization"},"image":{"@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp","keywords":["core loss","eddy currents","electrical steel","hysteresis loss","insulating coating","lamination","magnetic flux","power transformer","transformer efficiency","transformer steel"],"articleSection":["Blog"],"inLanguage":"ms-MY"},{"@type":"WebPage","@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/","url":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/","name":"Why an insulating coating is mandatory for transformer steel - Zhongtongweiye","isPartOf":{"@id":"https:\/\/www.jycomat.com\/bg\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/#primaryimage"},"image":{"@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp","datePublished":"2026-09-20T08:52:17+00:00","description":"Why an insulating coating is mandatory for transformer steel Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.","breadcrumb":{"@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/#breadcrumb"},"inLanguage":"ms-MY","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/"]}]},{"@type":"ImageObject","inLanguage":"ms-MY","@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/#primaryimage","url":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp","contentUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp","width":800,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/www.jycomat.com\/why-an-insulating-coating-is-mandatory-for-transformer-steel\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.jycomat.com\/"},{"@type":"ListItem","position":2,"name":"Why an insulating coating is mandatory for transformer steel"}]},{"@type":"WebSite","@id":"https:\/\/www.jycomat.com\/bg\/#website","url":"https:\/\/www.jycomat.com\/bg\/","name":"Pengeluar &amp; Pengeksport Silikon Keluli China | Produk Keluli | Zhongtongweiye","description":"","publisher":{"@id":"https:\/\/www.jycomat.com\/bg\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.jycomat.com\/bg\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ms-MY"},{"@type":"Organization","@id":"https:\/\/www.jycomat.com\/bg\/#organization","name":"Pengeluar &amp; Pengeksport Silikon Keluli China | Produk Keluli | Zhongtongweiye","url":"https:\/\/www.jycomat.com\/bg\/","logo":{"@type":"ImageObject","inLanguage":"ms-MY","@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/logo\/image\/","url":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/08\/cropped-favicon.webp","contentUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/08\/cropped-favicon.webp","width":512,"height":512,"caption":"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye"},"image":{"@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/person\/2d5d62a164d46f464cb79f7e71f46f2d","name":"adminwxzd","image":{"@type":"ImageObject","inLanguage":"ms-MY","@id":"https:\/\/secure.gravatar.com\/avatar\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g","caption":"adminwxzd"},"sameAs":["https:\/\/www.jycomat.com"],"url":"https:\/\/www.jycomat.com\/ms\/author\/adminwxzd\/"}]}},"uagb_featured_image_src":{"full":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp",800,800,false],"thumbnail":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3-300x300.webp",300,300,true],"medium":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3-500x500.webp",500,500,true],"medium_large":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3-768x768.webp",768,768,true],"large":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp",800,800,false],"1536x1536":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp",800,800,false],"2048x2048":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3.webp",800,800,false],"trp-custom-language-flag":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Non-Oriented-Electrical-Steel-8-3-12x12.webp",12,12,true]},"uagb_author_info":{"display_name":"adminwxzd","author_link":"https:\/\/www.jycomat.com\/ms\/author\/adminwxzd\/"},"uagb_comment_info":0,"uagb_excerpt":"Why an Insulating Coating Is Mandatory for Transformer Steel Transformer steel sits at the heart of every electrical grid. It carries magnetic flux with very low loss. However, bare steel alone cannot do this job well. An insulating coating is therefore mandatory. This thin layer solves several critical problems at once. It also protects the&hellip;","_links":{"self":[{"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/posts\/3566","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/comments?post=3566"}],"version-history":[{"count":1,"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/posts\/3566\/revisions"}],"predecessor-version":[{"id":3578,"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/posts\/3566\/revisions\/3578"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/media\/3567"}],"wp:attachment":[{"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/media?parent=3566"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/categories?post=3566"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jycomat.com\/ms\/wp-json\/wp\/v2\/tags?post=3566"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}