How Energy Saving CRGO Silicon Steel Cuts Down Grid Power Waste

CRGO transformer core loss wastes 2–4% of all electricity generated worldwide. That waste runs 24/7, whether the transformer carries load or not. Consequently, grid operators target no-load loss as the first efficiency lever. At Jiangsu Zhongtong Weiye Special Steel Co., Ltd., we supply the grain-oriented steel that does the job. Here is the math.

Where Grid Transformers Lose Power

A transformer loses power in two ways:

  • No-load (core) loss: runs constantly, from magnetizing the steel.
  • Load (copper) loss: scales with current through the windings.

CRGO cuts no-load loss. Furthermore, premium CRGO cuts it by 30–50% versus older grades. Consequently, every transformer in a city distribution network benefits.

Grade Comparison

CRGO grade Thickness Core loss (W/kg @1.7T, 50Hz)
35Q145 0.35 mm 1.45
30Q120 0.30 mm 1.20
27QG110 0.27 mm 1.10
23QG090 0.23 mm 0.90

Consequently, thinner, laser-scored grades waste less. Furthermore, a 10 MVA transformer on 27QG110 saves ~15 kW no-load loss versus 35Q145.

The 24/7 Cost of No-Load Loss

15 kW × 8,760 hours = 131,400 kWh per year. At $0.10/kWh, that is $13,140 per year per transformer. Furthermore, a city with 1,000 distribution transformers wastes $13 million annually. Consequently, premium CRGO pays back its extra cost in 2–3 years.

Environmental Impact

Less wasted power means less generated power. Furthermore, most grid electricity still comes from fossil plants. Consequently, cutting core loss directly cuts CO2 emissions. A single 10 MVA transformer on premium CRGO avoids ~100 tons of CO2 per year.

CRGO transformer loss

What We Supply

We ship grain-oriented electrical steel coil:

  • Grades: 27QG110, 30Q120, 35Q145.
  • Thickness: 0.23–0.35 mm.
  • Slit to core width with ±0.05 mm tolerance.
  • Coil ID 508 mm or 406 mm.

Furthermore, we pack for ocean freight with VCI paper.

What We Do Not Do

We do not:

  • Manufacture or rewind transformers.
  • Supply amorphous metal cores.
  • Build transformer substations.

Consequently, we are your upstream CRGO coil supplier, not your competitor.

Specify Your Grid Transformer Steel

Tell us:

  1. Transformer kVA and voltage class.
  2. Required no-load loss (W).
  3. Core strip width and coil ID.
  4. Annual volume.

We will recommend the correct CRGO grade and quote.

  • Email: vera.liang@ztwysteel.com
  • Location: Xishan District, Wuxi, Jiangsu, China
  • Supply range: CRGO grain-oriented steel, CRNGO non-oriented steel, slit strip
  • Slitting tolerance: ±0.05 mm
  • Documentation: MTC with core loss, thickness, width, and insulation coating

We reply within one working day.