{"id":4407,"date":"2026-09-21T05:04:00","date_gmt":"2026-09-21T05:04:00","guid":{"rendered":"https:\/\/www.jycomat.com\/?p=4407"},"modified":"2026-09-21T05:04:01","modified_gmt":"2026-09-21T05:04:01","slug":"influence-du-facteur-dempilement-sur-le-rendement-energetique-et-le-bruit-des-noyaux-de-transformateurs","status":"publish","type":"post","link":"https:\/\/www.jycomat.com\/fr\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/","title":{"rendered":"Influence du facteur d'empilement sur le rendement \u00e9nerg\u00e9tique et le niveau sonore des noyaux de transformateurs"},"content":{"rendered":"<p>Le facteur d'empilement est un indice d'assemblage essentiel pour les noyaux en acier magn\u00e9tique des transformateurs. Il correspond au rapport entre l'\u00e9paisseur effective de l'acier et l'\u00e9paisseur totale du noyau empil\u00e9. Ce param\u00e8tre influe consid\u00e9rablement sur le rendement \u00e9nerg\u00e9tique et le niveau sonore du transformateur.<\/p>\n<p>Un facteur d'empilement \u00e9lev\u00e9 am\u00e9liore efficacement le rendement \u00e9nerg\u00e9tique du transformateur. Un facteur d'empilement plus \u00e9lev\u00e9 signifie moins d'espaces d'air \u00e0 l'int\u00e9rieur du noyau. Les espaces d'air pr\u00e9sentent une faible conductivit\u00e9 magn\u00e9tique et une r\u00e9sistance magn\u00e9tique \u00e9lev\u00e9e. La r\u00e9duction des espaces d'air diminue la r\u00e9sistance magn\u00e9tique globale du noyau. Cela permet de r\u00e9duire le courant d'excitation et les pertes \u00e0 vide.<\/p>\n<p>Un faible facteur d'empilement augmente la r\u00e9sistance magn\u00e9tique parasite des noyaux. Un empilement mal ajust\u00e9 entra\u00eene l'apparition de nombreux petits espaces. La transmission du flux magn\u00e9tique se heurte \u00e0 une forte r\u00e9sistance. Le transformateur a besoin d'une puissance d'excitation plus importante pour fonctionner normalement. La consommation d'\u00e9nergie augmente consid\u00e9rablement.<\/p>\n<p>Le facteur d'empilement influe directement sur le bruit de fonctionnement du transformateur. Un empilement dense et uniforme r\u00e9duit les espaces internes du noyau. Il att\u00e9nue les vibrations magn\u00e9tiques et la r\u00e9sonance lors de la magn\u00e9tisation. Le bruit global du transformateur s'en trouve consid\u00e9rablement r\u00e9duit.<\/p>\n<p>Un facteur d'empilement trop faible entra\u00eene un rel\u00e2chement de la structure du noyau. Les t\u00f4les d'acier, ainsi rel\u00e2ch\u00e9es, vibrent ind\u00e9pendamment les unes des autres sous l'effet de champs magn\u00e9tiques alternatifs. L'amplitude des vibrations augmente consid\u00e9rablement. Cela g\u00e9n\u00e8re un bruit de basse fr\u00e9quence manifeste et des vibrations de l'\u00e9quipement.<\/p>\n<p>Cependant, le facteur d'empilement ne peut pas atteindre une valeur infiniment \u00e9lev\u00e9e. Un empilement trop serr\u00e9 provoque des contraintes internes dans l'acier magn\u00e9tique. Ces contraintes d\u00e9truisent partiellement la structure des domaines magn\u00e9tiques, ce qui entra\u00eene une l\u00e9g\u00e8re augmentation des pertes locales dans le noyau.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4225 size-full\" src=\"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp\" alt=\"Noyaux de transformateurs\" width=\"925\" height=\"925\" srcset=\"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp 925w, https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3-500x500.webp 500w, https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3-300x300.webp 300w, https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3-768x768.webp 768w, https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3-12x12.webp 12w\" sizes=\"auto, (max-width: 925px) 100vw, 925px\" \/><\/p>\n<p>Le facteur d'empilement optimal pour les transformateurs se situe entre 0,97 et 0,99. Cette plage permet d'atteindre un \u00e9quilibre entre la densit\u00e9 d'empilement et le contr\u00f4le des contraintes. Elle offre les meilleurs r\u00e9sultats en mati\u00e8re d'\u00e9conomies d'\u00e9nergie et de r\u00e9duction du bruit.<\/p>\n<p>Dans l'ensemble, un facteur d'empilement adapt\u00e9 est essentiel pour obtenir des noyaux de transformateurs \u00e0 haut rendement et \u00e0 faible niveau sonore. Un processus d'empilement standard garantit un fonctionnement stable \u00e0 long terme des \u00e9quipements.<\/p>","protected":false},"excerpt":{"rendered":"<p>Stacking factor is a key assembly index of transformer electrical steel cores. It refers to the ratio of effective steel thickness to total stacked core thickness. This parameter greatly affects transformer energy efficiency and noise level. High stacking factor improves transformer energy efficiency effectively. Higher stacking factor means fewer air gaps inside the core. Air [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4225,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","footnotes":""},"categories":[5],"tags":[43],"class_list":["post-4407","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-silicon-steel"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores - Zhongtongweiye<\/title>\n<meta name=\"description\" content=\"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.jycomat.com\/fr\/influence-du-facteur-dempilement-sur-le-rendement-energetique-et-le-bruit-des-noyaux-de-transformateurs\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores - Zhongtongweiye\" \/>\n<meta property=\"og:description\" content=\"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.jycomat.com\/fr\/influence-du-facteur-dempilement-sur-le-rendement-energetique-et-le-bruit-des-noyaux-de-transformateurs\/\" \/>\n<meta property=\"og:site_name\" content=\"Silicon Steel - Zhongtongweiye\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-21T05:04:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-21T05:04:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"925\" \/>\n\t<meta property=\"og:image:height\" content=\"925\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"adminwxzd\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"adminwxzd\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/\"},\"author\":{\"name\":\"adminwxzd\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/person\\\/2d5d62a164d46f464cb79f7e71f46f2d\"},\"headline\":\"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores\",\"datePublished\":\"2026-09-21T05:04:00+00:00\",\"dateModified\":\"2026-09-21T05:04:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/\"},\"wordCount\":264,\"publisher\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Mold-Steel-3.webp\",\"keywords\":[\"silicon steel\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/\",\"name\":\"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores - Zhongtongweiye\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Mold-Steel-3.webp\",\"datePublished\":\"2026-09-21T05:04:00+00:00\",\"dateModified\":\"2026-09-21T05:04:01+00:00\",\"description\":\"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Mold-Steel-3.webp\",\"contentUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Mold-Steel-3.webp\",\"width\":925,\"height\":925},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.jycomat.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#website\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/\",\"name\":\"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#organization\",\"name\":\"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/cropped-favicon.webp\",\"contentUrl\":\"https:\\\/\\\/www.jycomat.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/cropped-favicon.webp\",\"width\":512,\"height\":512,\"caption\":\"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye\"},\"image\":{\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.jycomat.com\\\/bg\\\/#\\\/schema\\\/person\\\/2d5d62a164d46f464cb79f7e71f46f2d\",\"name\":\"adminwxzd\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g\",\"caption\":\"adminwxzd\"},\"sameAs\":[\"https:\\\/\\\/www.jycomat.com\"],\"url\":\"https:\\\/\\\/www.jycomat.com\\\/fr\\\/author\\\/adminwxzd\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Influence du facteur d'empilement sur le rendement \u00e9nerg\u00e9tique et le niveau sonore des noyaux de transformateurs - Zhongtongweiye","description":"Influence du facteur d'empilement sur le rendement \u00e9nerg\u00e9tique et le niveau sonore des noyaux de transformateurs. Lisez cet article pour en savoir plus sur l'acier au silicium. Zhongtongweiye partage ses connaissances professionnelles du secteur et ses conseils techniques.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.jycomat.com\/fr\/influence-du-facteur-dempilement-sur-le-rendement-energetique-et-le-bruit-des-noyaux-de-transformateurs\/","og_locale":"fr_FR","og_type":"article","og_title":"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores - Zhongtongweiye","og_description":"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores Read this article to learn about Silicon Steel . Zhongtongweiye shares professional industry knowledge and technical guidance.","og_url":"https:\/\/www.jycomat.com\/fr\/influence-du-facteur-dempilement-sur-le-rendement-energetique-et-le-bruit-des-noyaux-de-transformateurs\/","og_site_name":"Silicon Steel - Zhongtongweiye","article_published_time":"2026-09-21T05:04:00+00:00","article_modified_time":"2026-09-21T05:04:01+00:00","og_image":[{"width":925,"height":925,"url":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp","type":"image\/webp"}],"author":"adminwxzd","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"adminwxzd","Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/#article","isPartOf":{"@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/"},"author":{"name":"adminwxzd","@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/person\/2d5d62a164d46f464cb79f7e71f46f2d"},"headline":"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores","datePublished":"2026-09-21T05:04:00+00:00","dateModified":"2026-09-21T05:04:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/"},"wordCount":264,"publisher":{"@id":"https:\/\/www.jycomat.com\/bg\/#organization"},"image":{"@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp","keywords":["silicon steel"],"articleSection":["Blog"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/","url":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/","name":"Influence du facteur d'empilement sur le rendement \u00e9nerg\u00e9tique et le niveau sonore des noyaux de transformateurs - Zhongtongweiye","isPartOf":{"@id":"https:\/\/www.jycomat.com\/bg\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/#primaryimage"},"image":{"@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/#primaryimage"},"thumbnailUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp","datePublished":"2026-09-21T05:04:00+00:00","dateModified":"2026-09-21T05:04:01+00:00","description":"Influence du facteur d'empilement sur le rendement \u00e9nerg\u00e9tique et le niveau sonore des noyaux de transformateurs. Lisez cet article pour en savoir plus sur l'acier au silicium. Zhongtongweiye partage ses connaissances professionnelles du secteur et ses conseils techniques.","breadcrumb":{"@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/#primaryimage","url":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp","contentUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp","width":925,"height":925},{"@type":"BreadcrumbList","@id":"https:\/\/www.jycomat.com\/influence-of-stacking-factor-on-energy-efficiency-and-noise-of-transformer-cores\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.jycomat.com\/"},{"@type":"ListItem","position":2,"name":"Influence of Stacking Factor on Energy Efficiency and Noise of Transformer Cores"}]},{"@type":"WebSite","@id":"https:\/\/www.jycomat.com\/bg\/#website","url":"https:\/\/www.jycomat.com\/bg\/","name":"Fabricant et exportateur chinois d'acier au silicium | Produits sid\u00e9rurgiques | Zhongtongweiye","description":"","publisher":{"@id":"https:\/\/www.jycomat.com\/bg\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.jycomat.com\/bg\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.jycomat.com\/bg\/#organization","name":"Fabricant et exportateur chinois d'acier au silicium | Produits sid\u00e9rurgiques | Zhongtongweiye","url":"https:\/\/www.jycomat.com\/bg\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/logo\/image\/","url":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/08\/cropped-favicon.webp","contentUrl":"https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/08\/cropped-favicon.webp","width":512,"height":512,"caption":"China Silicon Steel Manufacturer &amp; Exporter | Steel Products | Zhongtongweiye"},"image":{"@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.jycomat.com\/bg\/#\/schema\/person\/2d5d62a164d46f464cb79f7e71f46f2d","name":"adminwxzd","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/847b6c0378774b851fa76da74f7b1b7c8b431407f8d57e35eeb158ec30811636?s=96&d=mm&r=g","caption":"adminwxzd"},"sameAs":["https:\/\/www.jycomat.com"],"url":"https:\/\/www.jycomat.com\/fr\/author\/adminwxzd\/"}]}},"uagb_featured_image_src":{"full":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp",925,925,false],"thumbnail":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3-300x300.webp",300,300,true],"medium":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3-500x500.webp",500,500,true],"medium_large":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3-768x768.webp",768,768,true],"large":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp",925,925,false],"1536x1536":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp",925,925,false],"2048x2048":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3.webp",925,925,false],"trp-custom-language-flag":["https:\/\/www.jycomat.com\/wp-content\/uploads\/2026\/09\/Mold-Steel-3-12x12.webp",12,12,true]},"uagb_author_info":{"display_name":"adminwxzd","author_link":"https:\/\/www.jycomat.com\/fr\/author\/adminwxzd\/"},"uagb_comment_info":0,"uagb_excerpt":"Stacking factor is a key assembly index of transformer electrical steel cores. It refers to the ratio of effective steel thickness to total stacked core thickness. This parameter greatly affects transformer energy efficiency and noise level. High stacking factor improves transformer energy efficiency effectively. Higher stacking factor means fewer air gaps inside the core. Air\u2026","_links":{"self":[{"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/posts\/4407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/comments?post=4407"}],"version-history":[{"count":1,"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/posts\/4407\/revisions"}],"predecessor-version":[{"id":4408,"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/posts\/4407\/revisions\/4408"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/media\/4225"}],"wp:attachment":[{"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/media?parent=4407"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/categories?post=4407"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jycomat.com\/fr\/wp-json\/wp\/v2\/tags?post=4407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}